Features

  • High online efficiency: Reduces utlility costs, generates less heat.
  • Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Pure sine wave output on battery: Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
  • LCD Status Display: Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
  • Cold-start capable: Provides temporary battery power when the utility power is out.
  • Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.

Availability

  • Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
  • Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Disconnected battery notification: Warns when a battery is not available to provide backup power.

Manageability

  • Network manageable: Provides remote power management of the UPS over the network.
  • Audible alarms: Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
  • LED status indicators: Quickly understand unit and power status with visual indicators.
  • Serial connectivity: Provides management of the UPS via a serial port.
  • USB connectivity: Provides management of the UPS via a USB port (not available on all models).
  • Disconnected battery notification: Warns when a battery is not available to provide backup power.

Serviceability

  • User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.
  • Resettable circuit breakers: Enables a quick recovery from overload events.
  • Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Adaptability

  • Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Safety

  • Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Technical Specifications

Output

  • Output Power Capacity: 2100 Watts / 3000 VA
  • Max Configurable Power: 2100 Watts / 3000 VA
  • Nominal Output Voltage: 230V
  • Output Voltage Distortion: Less than 5% at full load
  • Output Frequency (sync to mains): 50 Hz
  • Topology: Line Interactive
  • Waveform Type: Sine wave
  • Output Connections: (6) IEC 320 C13, (1) IEC 320 C19

Input

  • Nominal Input Voltage: 230V
  • Input Frequency: 47 – 63 Hz
  • Input Connections: IEC-320 C20
  • Input voltage range for main operations: 180 – 287V
  • Input voltage adjustable range for mains operation: 170 – 300V

Batteries & Runtime

  • Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Typical recharge time: 3 hour(s)
  • Replacement Battery(Service center technician only): APCRBC151
  • Replacement Battery: RBC7
  • RBC